Service Packages
Service Packages & What to Expect During a Service Call
For our customer’s convenience, we have bundled some services together to make most efficient use of your valuable time. During a service call, depending on your circumstances, you can expect one of the following packages to be performed:
Nickel’s Basic – 30 minute appointment
This is our most basic service offered. It typically includes:
- Filter change and basic equipment cleaning
- Operations check of the Heat pump/AC unit through a super heat and subcool check. Completed using gauges and temperature sensors.
- System owner report of any problems or potential issues
Nickel Better – 1 – 2 hour appointment
This service is for systems 2 or more years old and/or for a system we did not originally install:
- Filter change and basic equipment cleaning
- Operations check of the Heat pump/AC unit through a super heat and subcool check. Completed using gauges and temperature sensors.
- Indoor coil will be cleaned with 1 can of evaporator coil cleaner and blow out of the condensate drain with the use of a gallo gun.
- Pressure check of the system before and after the cleaning of the coil to confirm better air flow.
- System owner report of any outstanding problems or potential issues
Nickel’s Best – 2 – 3 hour appointment or 4 – 5 hour appointment (system dependent)
This service is for systems 5 or more years old and/or excessively dirty systems.
- Operations check of the Heat pump/AC unit through a super heat and subcool check. Completed using gauges and temperature sensors.
- System filter will be changed.
- Indoor and outdoor coils will be cleaned with 1 can of designated coil cleaner and blow out condensate drain with the use of a gallo gun.
- If indoor coil is too dirty to be cleaned with just the use of chemicals, technician will pump down the systems charge into the condensing unit and cut the evaporator lines.
- We remove the outdoor coil and pressure wash it, adjusting any bent fins with a fin comb.
- If the condensing unit is too dirty to be cleaned with just the use of chemicals, technician will remove the exterior panels and pressure wash the coil.
- The system will then be braised back together with the addition of a liquid line dryer. The lines will then be vacuumed to under 500 microns, ensuring the absence of non-condensables in the system.
- Additional refrigerant may be added on start up to optimize performance.
- Pressure check of the system before and after the cleaning of the coil to confirm better air flow.